SR 90 EB over Over CSX Railroad
PoorErie County, Pennsylvania · North East Township · Structure no. 000000000016112
- Built
- 1959
- 66 years old, rebuilt 1982
- Condition
- Poor
- inspected June 2024
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 204 ft
- 3 main spans
- Daily traffic
- 11,394
- 2024 count
- Owner
- State
- State Highway Agency
About this bridge
SR 90 EB over Over CSX Railroad is a steel stringer/multi-beam or girder carrying SR 90 EB over Over CSX Railroad in Erie County, Pennsylvania. It was built in 1959 and reconstructed in 1982, so it is 66 years old, older than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 11,394 vehicles a day, roughly 44% of them trucks, projected to reach 6,658 by 2032. The structure is 204 ft (62.2 m) long and 56 ft wide. If it were closed, the detour would be 1.9 mi (3 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR 90 EB over Over CSX Railroad built?
It was built in 1959, making it 66 years old in 2025. It was reconstructed in 1982.
What condition is SR 90 EB over Over CSX Railroad in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in June 2024.
How much traffic does SR 90 EB over Over CSX Railroad carry?
About 11,394 vehicles per day (2024 count), of which roughly 44% are trucks.
How long is SR 90 EB over Over CSX Railroad?
The structure is 204 ft (62.2 m) long with a longest span of 94 ft (28.7 m) and a deck 56 ft wide.
Who owns SR 90 EB over Over CSX Railroad?
It is owned by the State Highway Agency.