US Bridges

SR 3007 over Potts Run

Good

Clearfield County, Pennsylvania · Carnwath · Structure no. 000000000046095

Built
2010
15 years old
Condition
Good
inspected August 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
42 ft
1 main span
Daily traffic
77
2024 count
Owner
State
State Highway Agency

About this bridge

SR 3007 over Potts Run is a prestressed concrete box beam or girders - multiple carrying SR 3007 over Potts Run in Clearfield County, Pennsylvania. It was built in 2010, so it is 15 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 77 vehicles a day, roughly 2% of them trucks, projected to reach 125 by 2042. The structure is 42 ft (12.8 m) long and 25 ft wide. If it were closed, the detour would be 11.8 mi (19 km).

CarriesSR 3007
CrossesPotts Run
LocationCarnwath
RouteState Highway 0
Coordinates40.86284, -78.51112
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure7 GoodSome minor problems.
Channel and channel protection7 GoodSome minor problems.
Last inspectionAugust 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating85 US tons
Inventory rating41 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHL 93
Structure length42 ft (12.8 m)
Longest span42 ft (12.8 m)
Deck width25 ft (7.7 m)
Roadway width22 ft (6.7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic77 (2024)
Projected traffic125 by 2042
Trucks2%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed11.8 mi (19 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 3007 over Potts Run built?

It was built in 2010, making it 15 years old in 2025.

What condition is SR 3007 over Potts Run in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in August 2024.

How much traffic does SR 3007 over Potts Run carry?

About 77 vehicles per day (2024 count), of which roughly 2% are trucks.

How long is SR 3007 over Potts Run?

The structure is 42 ft (12.8 m) long with a longest span of 42 ft (12.8 m) and a deck 25 ft wide.

Who owns SR 3007 over Potts Run?

It is owned by the State Highway Agency.