US Bridges

SR 3011 over US 322-US 322

Fair

Centre County, Pennsylvania · Lemont · Structure no. 000000000009715

Built
1985
40 years old
Condition
Fair
inspected June 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
254 ft
4 main spans
Daily traffic
5,446
2024 count
Owner
State
State Highway Agency

About this bridge

SR 3011 over US 322-US 322 is a prestressed concrete box beam or girders - multiple carrying SR 3011 over US 322-US 322 in Centre County, Pennsylvania. It was built in 1985, so it is 40 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 5,446 vehicles a day, roughly 1% of them trucks, projected to reach 9,571 by 2043. The structure is 254 ft (77.4 m) long and 38 ft wide. If it were closed, the detour would be 6.8 mi (11 km).

CarriesSR 3011
CrossesUS 322-US 322
LocationLemont
RouteState Highway 0
Coordinates40.80262, -77.82717
Functional classUrban Collector

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJune 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment7: Better than present minimum criteria
Operating rating61.9 US tons
Inventory rating37 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20
Structure length254 ft (77.4 m)
Longest span87 ft (26.5 m)
Deck width38 ft (11.5 m)
Roadway width34 ft (10.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic5,446 (2024)
Projected traffic9,571 by 2043
Trucks1%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed6.8 mi (11 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was SR 3011 over US 322-US 322 built?

It was built in 1985, making it 40 years old in 2025.

What condition is SR 3011 over US 322-US 322 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2023.

How much traffic does SR 3011 over US 322-US 322 carry?

About 5,446 vehicles per day (2024 count), of which roughly 1% are trucks.

How long is SR 3011 over US 322-US 322?

The structure is 254 ft (77.4 m) long with a longest span of 87 ft (26.5 m) and a deck 38 ft wide.

Who owns SR 3011 over US 322-US 322?

It is owned by the State Highway Agency.