US Bridges

SR 8016 over SR 3016 & Horner St.

Fair

Cambria County, Pennsylvania · Bedford St.Exit Johnstown · Structure no. 000000000008815

Built
1972
53 years old, rebuilt 1994
Condition
Fair
inspected March 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
222 ft
1 main span
Daily traffic
4,852
2024 count
Owner
State
State Highway Agency

About this bridge

SR 8016 over SR 3016 & Horner St. is a steel stringer/multi-beam or girder carrying SR 8016 over SR 3016 & Horner St. in Cambria County, Pennsylvania. It was built in 1972 and reconstructed in 1994, so it is 53 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 4,852 vehicles a day, roughly 3% of them trucks, projected to reach 5,847 by 2032. The structure is 222 ft (67.7 m) long and 33 ft wide.

CarriesSR 8016
CrossesSR 3016 & Horner St.
LocationBedford St.Exit Johnstown
RouteState Highway 0
Coordinates40.32333, -78.91333
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure7 GoodSome minor problems.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionMarch 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating107 US tons
Inventory rating64 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1 (+1 approach)
Design loadHS 20
Structure length222 ft (67.7 m)
Longest span117 ft (35.7 m)
Deck width33 ft (10.1 m)
Roadway width29 ft (8.9 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic4,852 (2024)
Projected traffic5,847 by 2032
Trucks3%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed—
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was SR 8016 over SR 3016 & Horner St. built?

It was built in 1972, making it 53 years old in 2025. It was reconstructed in 1994.

What condition is SR 8016 over SR 3016 & Horner St. in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2023.

How much traffic does SR 8016 over SR 3016 & Horner St. carry?

About 4,852 vehicles per day (2024 count), of which roughly 3% are trucks.

How long is SR 8016 over SR 3016 & Horner St.?

The structure is 222 ft (67.7 m) long with a longest span of 117 ft (35.7 m) and a deck 33 ft wide.

Who owns SR 8016 over SR 3016 & Horner St.?

It is owned by the State Highway Agency.