SR0356 over Sarver Run
FairButler County, Pennsylvania · Sarverville NO.1 · Structure no. 000000000007932
- Built
- 1938
- 87 years old
- Condition
- Fair
- inspected March 2023
- Type
- Tee Beam
- Concrete
- Length
- 36 ft
- 1 main span
- Daily traffic
- 10,782
- 2023 count
- Owner
- State
- State Highway Agency
About this bridge
SR0356 over Sarver Run is a concrete tee beam carrying SR0356 over Sarver Run in Butler County, Pennsylvania. It was built in 1938, so it is 87 years old, older than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 10,782 vehicles a day, roughly 15% of them trucks, projected to reach 15,942 by 2032. The structure is 36 ft (11 m) long and 36 ft wide. If it were closed, the detour would be 3.7 mi (6 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Channel and channel protection | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR0356 over Sarver Run built?
It was built in 1938, making it 87 years old in 2025.
What condition is SR0356 over Sarver Run in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2023.
How much traffic does SR0356 over Sarver Run carry?
About 10,782 vehicles per day (2023 count), of which roughly 15% are trucks.
How long is SR0356 over Sarver Run?
The structure is 36 ft (11 m) long with a longest span of 31 ft (9.4 m) and a deck 36 ft wide.
Who owns SR0356 over Sarver Run?
It is owned by the State Highway Agency.