US Bridges

Canton ST over Fall Brook

Good

Bradford County, Pennsylvania · Troy Boro · Structure no. 000000000054100

Built
2018
7 years old
Condition
Good
inspected May 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
37 ft
1 main span
Daily traffic
6,522
2024 count
Owner
State
State Highway Agency

About this bridge

Canton ST over Fall Brook is a prestressed concrete box beam or girders - multiple carrying Canton ST over Fall Brook in Bradford County, Pennsylvania. It was built in 2018, so it is 7 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 6,522 vehicles a day, roughly 8% of them trucks, projected to reach 8,086 by 2037. The structure is 37 ft (11.3 m) long and 46 ft wide. If it were closed, the detour would be 42.3 mi (68 km).

CarriesCanton ST
CrossesFall Brook
LocationTroy Boro
RouteState Highway 14
Coordinates41.77728, -76.79214
Functional classRural Minor Arterial

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure9 ExcellentNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionMay 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60.7 US tons
Inventory rating46.7 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHL 93
Structure length37 ft (11.3 m)
Longest span33 ft (10.1 m)
Deck width46 ft (14 m)
Roadway width34 ft (10.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic6,522 (2024)
Projected traffic8,086 by 2037
Trucks8%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed42.3 mi (68 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byPrivate (other than railroad)
Historic statusNot eligible for the National Register of Historic Places
Work proposedOther structural work, including hydraulic replacements
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Canton ST over Fall Brook built?

It was built in 2018, making it 7 years old in 2025.

What condition is Canton ST over Fall Brook in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2024.

How much traffic does Canton ST over Fall Brook carry?

About 6,522 vehicles per day (2024 count), of which roughly 8% are trucks.

How long is Canton ST over Fall Brook?

The structure is 37 ft (11.3 m) long with a longest span of 33 ft (10.1 m) and a deck 46 ft wide.

Who owns Canton ST over Fall Brook?

It is owned by the State Highway Agency and maintained by the Private (other than railroad).