US Bridges

West Road over CSX RR

PoorPosted for load

Beaver County, Pennsylvania · P02302 Old Furnace/Westrd · Structure no. 000000000003873

Built
1939
86 years old
Condition
Poor
inspected October 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
94 ft
1 main span
Daily traffic
10
2016 count
Owner
Railroad
Railroad

About this bridge

West Road over CSX RR is a steel stringer/multi-beam or girder carrying West Road over CSX RR in Beaver County, Pennsylvania. It was built in 1939, so it is 86 years old, older than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 3 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: posted for load restriction.

It carries about 10 vehicles a day, roughly 1% of them trucks, projected to reach 10 by 2038. The structure is 94 ft (28.7 m) long and 14 ft wide. If it were closed, the detour would be 98.8 mi (159 km).

CarriesWest Road
CrossesCSX RR
LocationP02302 Old Furnace/Westrd
RouteCity Street 0
Coordinates40.7969, -80.1676
Functional classRural Local

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure3 SeriousLoss of section, deterioration, spalling or scour have seriously affected primary structural components.
Last inspectionOctober 2024
Inspection intervalevery 24 months
Operating statusPosted for load restriction
ScourBridge not over waterway
Structural evaluation2: Basically intolerable, requiring high priority of replacement
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment4: Meets minimum tolerable limits to be left in place as is
Operating rating10 US tons
Inventory rating6 US tons

Structure

MaterialSteel
DeckWood or timber
Main spans1 (+4 approach)
Design loadHS 20
Structure length94 ft (28.7 m)
Longest span35 ft (10.7 m)
Deck width14 ft (4.3 m)
Roadway width12 ft (3.8 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic10 (2016)
Projected traffic10 by 2038
Trucks1%
Lanes on structure1
Traffic directionOne-lane bridge for two-way traffic
CarriesHighway
CrossesRailroad
Detour if closed98.8 mi (159 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerRailroad
Maintained byRailroad
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$230,000
NavigationNo navigation control on waterway

Frequently asked questions

When was West Road over CSX RR built?

It was built in 1939, making it 86 years old in 2025.

What condition is West Road over CSX RR in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in October 2024.

How much traffic does West Road over CSX RR carry?

About 10 vehicles per day (2016 count), of which roughly 1% are trucks.

How long is West Road over CSX RR?

The structure is 94 ft (28.7 m) long with a longest span of 35 ft (10.7 m) and a deck 14 ft wide.

Who owns West Road over CSX RR?

It is owned by the Railroad.