South Millvale Av over N-S RR E Busway Gross ST
FairAllegheny County, Pennsylvania · 101 S Millvale Ave Bridge · Structure no. 000000000002452
- Built
- 1927
- 98 years old, rebuilt 2007
- Condition
- Fair
- inspected March 2024
- Type
- Girder and Floorbeam System
- Steel
- Length
- 460 ft
- 7 main spans
- Daily traffic
- 5,525
- 2006 count
- Owner
- City
- City or Municipal Highway Agency
About this bridge
South Millvale Av over N-S RR E Busway Gross ST is a steel girder and floorbeam system carrying South Millvale Av over N-S RR E Busway Gross ST in Allegheny County, Pennsylvania. It was built in 1927 and reconstructed in 2007, so it is 98 years old, older than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 5,525 vehicles a day, roughly 6% of them trucks, projected to reach 7,000 by 2026. The structure is 460 ft (140.2 m) long and 56 ft wide. If it were closed, the detour would be 3.1 mi (5 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was South Millvale Av over N-S RR E Busway Gross ST built?
It was built in 1927, making it 98 years old in 2025. It was reconstructed in 2007.
What condition is South Millvale Av over N-S RR E Busway Gross ST in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2024.
How much traffic does South Millvale Av over N-S RR E Busway Gross ST carry?
About 5,525 vehicles per day (2006 count), of which roughly 6% are trucks.
How long is South Millvale Av over N-S RR E Busway Gross ST?
The structure is 460 ft (140.2 m) long with a longest span of 90 ft (27.4 m) and a deck 56 ft wide.
Who owns South Millvale Av over N-S RR E Busway Gross ST?
It is owned by the City or Municipal Highway Agency.