US Bridges

Industrial Avenue over Canal

Poor

Lane County, Oregon · Industrial Ave. @ 42nd Av · Structure no. 20219 000 00000

Built
2005
20 years old
Condition
Poor
inspected August 2024
Type
Slab
Prestressed Concrete
Length
35 ft
1 main span
Daily traffic
1,398
2020 count
Owner
City
City or Municipal Highway Agency

About this bridge

Industrial Avenue over Canal is a prestressed concrete slab carrying Industrial Avenue over Canal in Lane County, Oregon. It was built in 2005, so it is 20 years old, younger than the Oregon average of 49.9 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 3 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

It carries about 1,398 vehicles a day, roughly 5% of them trucks, projected to reach 1,597 by 2025. The structure is 35 ft (10.7 m) long and 112 ft wide. If it were closed, the detour would be 3.7 mi (6 km).

CarriesIndustrial Avenue
CrossesCanal
LocationIndustrial Ave. @ 42nd Av
RouteCity Street 0
StateOregon
Coordinates44.05577, -122.96609
Functional classUrban Local

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck3 SeriousLoss of section, deterioration, spalling or scour have seriously affected primary structural components.
Superstructure3 SeriousLoss of section, deterioration, spalling or scour have seriously affected primary structural components.
Substructure7 GoodSome minor problems.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionAugust 2024
Inspection intervalevery 12 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation3: Basically intolerable, requiring high priority of corrective action
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating62.5 US tons
Inventory rating48.2 US tons

Structure

Structure typeSlab
MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans1
Design loadHS 25 or greater
Structure length35 ft (10.7 m)
Longest span35 ft (10.7 m)
Deck width112 ft (34 m)
Roadway width48 ft (14.5 m)
Vertical clearance over deck100 ft (30.5 m)

Traffic and service

Average daily traffic1,398 (2020)
Projected traffic1,597 by 2025
Trucks5%
Lanes on structure3
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.7 mi (6 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Industrial Avenue over Canal built?

It was built in 2005, making it 20 years old in 2025.

What condition is Industrial Avenue over Canal in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in August 2024.

How much traffic does Industrial Avenue over Canal carry?

About 1,398 vehicles per day (2020 count), of which roughly 5% are trucks.

How long is Industrial Avenue over Canal?

The structure is 35 ft (10.7 m) long with a longest span of 35 ft (10.7 m) and a deck 112 ft wide.

Who owns Industrial Avenue over Canal?

It is owned by the City or Municipal Highway Agency.