US Bridges

E. Boomer St. over Creek

Fair

Cleveland County, Oklahoma · 0.2 E S Main ST · Structure no. 249620000000000

Built
1995
30 years old
Condition
Fair
inspected November 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
33 ft
2 main spans
Daily traffic
100
2022 count
Owner
City
City or Municipal Highway Agency

About this bridge

E. Boomer St. over Creek is a steel stringer/multi-beam or girder carrying E. Boomer St. over Creek in Cleveland County, Oklahoma. It was built in 1995, so it is 30 years old, younger than the Oklahoma average of 47.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 100 vehicles a day, roughly 5% of them trucks, projected to reach 160 by 2042. The structure is 33 ft (10.1 m) long and 31 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesE. Boomer St.
CrossesCreek
Location0.2 E S Main ST
RouteCity Street E1382
Coordinates35.0128, -97.33376
Functional classUrban Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionNovember 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry2: Basically intolerable, requiring high priority of replacement
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating110.1 US tons
Inventory rating110.1 US tons

Structure

MaterialSteel
DeckSteel plate
Main spans2
Design loadH 15
Structure length33 ft (10.1 m)
Longest span16 ft (4.9 m)
Deck width31 ft (9.4 m)
Roadway width29 ft (8.8 m)
Vertical clearance over deck14 ft (4.1 m)

Traffic and service

Average daily traffic100 (2022)
Projected traffic160 by 2042
Trucks5%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCounty Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$281,000
NavigationNo navigation control on waterway

Frequently asked questions

When was E. Boomer St. over Creek built?

It was built in 1995, making it 30 years old in 2025.

What condition is E. Boomer St. over Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in November 2023.

How much traffic does E. Boomer St. over Creek carry?

About 100 vehicles per day (2022 count), of which roughly 5% are trucks.

How long is E. Boomer St. over Creek?

The structure is 33 ft (10.1 m) long with a longest span of 16 ft (4.9 m) and a deck 31 ft wide.

Who owns E. Boomer St. over Creek?

It is owned by the City or Municipal Highway Agency and maintained by the County Highway Agency.