Czech Hall Rd. over Creek

Fair

Canadian County, Oklahoma · 0.7 MI S of Reno · Structure no. 228040000000000

Built
1991
34 years old
Condition
Fair
inspected June 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
71 ft
1 main span
Daily traffic
3,700
2022 count
Owner
City
City or Municipal Highway Agency

About this bridge

Czech Hall Rd. over Creek is a prestressed concrete stringer/multi-beam or girder carrying Czech Hall Rd. over Creek in Canadian County, Oklahoma. It was built in 1991, so it is 34 years old, younger than the Oklahoma average of 47.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 3,700 vehicles a day, roughly 16% of them trucks, projected to reach 5,920 by 2042. The structure is 71 ft (21.6 m) long and 38 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesCzech Hall Rd.
CrossesCreek
Location0.7 MI S of Reno
RouteCity Street N2950
Coordinates35.45407, -97.74252
Functional classUrban Minor Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJune 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating36 US tons
Inventory rating21.5 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20
Structure length71 ft (21.6 m)
Longest span65 ft (19.8 m)
Deck width38 ft (11.5 m)
Roadway width36 ft (11 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,700 (2022)
Projected traffic5,920 by 2042
Trucks16%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$422,000
NavigationNo navigation control on waterway

Frequently asked questions

When was Czech Hall Rd. over Creek built?

It was built in 1991, making it 34 years old in 2025.

What condition is Czech Hall Rd. over Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2024.

How much traffic does Czech Hall Rd. over Creek carry?

About 3,700 vehicles per day (2022 count), of which roughly 16% are trucks.

How long is Czech Hall Rd. over Creek?

The structure is 71 ft (21.6 m) long with a longest span of 65 ft (19.8 m) and a deck 38 ft wide.

Who owns Czech Hall Rd. over Creek?

It is owned by the City or Municipal Highway Agency.