CR 418 (old US30) over Usr 30

Good

Van Wert County, Ohio · East of Inter 30&49-S · Structure no. 8100241

Built
1966
59 years old
Condition
Good
inspected October 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
295 ft
4 main spans
Daily traffic
318
2016 count
Owner
State
State Highway Agency

About this bridge

CR 418 (old US30) over Usr 30 is a steel continuous stringer/multi-beam or girder carrying CR 418 (old US30) over Usr 30 in Van Wert County, Ohio. It was built in 1966, so it is 59 years old, older than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 318 vehicles a day, roughly 6% of them trucks, projected to reach 441 by 2036. The structure is 295 ft (89.8 m) long and 36 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesCR 418 (old US30)
CrossesUsr 30
LocationEast of Inter 30&49-S
RouteCounty Highway C0418
StateOhio
Coordinates40.93513, -84.69897
Functional classRural Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionOctober 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating40.3 US tons
Inventory rating31.1 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20 + Mod
Structure length295 ft (89.8 m)
Longest span85 ft (25.9 m)
Deck width36 ft (11.1 m)
Roadway width30 ft (9.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic318 (2016)
Projected traffic441 by 2036
Trucks6%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was CR 418 (old US30) over Usr 30 built?

It was built in 1966, making it 59 years old in 2025.

What condition is CR 418 (old US30) over Usr 30 in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in October 2024.

How much traffic does CR 418 (old US30) over Usr 30 carry?

About 318 vehicles per day (2016 count), of which roughly 6% are trucks.

How long is CR 418 (old US30) over Usr 30?

The structure is 295 ft (89.8 m) long with a longest span of 85 ft (25.9 m) and a deck 36 ft wide.

Who owns CR 418 (old US30) over Usr 30?

It is owned by the State Highway Agency.