US Bridges

Bellwick RD CR 11 over IR80

Good

Trumbull County, Ohio · 1.21 MI E of SR 304 · Structure no. 7804113

Built
1970
55 years old, rebuilt 1999
Condition
Good
inspected May 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
311 ft
4 main spans
Daily traffic
136
2015 count
Owner
State
State Highway Agency

About this bridge

Bellwick RD CR 11 over IR80 is a steel continuous stringer/multi-beam or girder carrying Bellwick RD CR 11 over IR80 in Trumbull County, Ohio. It was built in 1970 and reconstructed in 1999, so it is 55 years old, older than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 136 vehicles a day, roughly 5% of them trucks, projected to reach 50,337 by 2035. The structure is 311 ft (94.9 m) long and 31 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesBellwick RD CR 11
CrossesIR80
Location1.21 MI E of SR 304
RouteCounty Highway C0011
StateOhio
Coordinates41.16829, -80.59743
Functional classUrban Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionMay 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment9: Superior to present desirable criteria
Operating rating39.2 US tons
Inventory rating28.5 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20 + Mod
Structure length311 ft (94.9 m)
Longest span90 ft (27.5 m)
Deck width31 ft (9.4 m)
Roadway width28 ft (8.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic136 (2015)
Projected traffic50,337 by 2035
Trucks5%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Bellwick RD CR 11 over IR80 built?

It was built in 1970, making it 55 years old in 2025. It was reconstructed in 1999.

What condition is Bellwick RD CR 11 over IR80 in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2024.

How much traffic does Bellwick RD CR 11 over IR80 carry?

About 136 vehicles per day (2015 count), of which roughly 5% are trucks.

How long is Bellwick RD CR 11 over IR80?

The structure is 311 ft (94.9 m) long with a longest span of 90 ft (27.5 m) and a deck 31 ft wide.

Who owns Bellwick RD CR 11 over IR80?

It is owned by the State Highway Agency.