US Bridges

Arlington Street over CSX Rr. (137)

Good

Summit County, Ohio · North of Forge Street · Structure no. 7760078

Built
1969
56 years old
Condition
Good
inspected February 2023
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
123 ft
3 main spans
Daily traffic
6,198
2015 count
Owner
City
City or Municipal Highway Agency

About this bridge

Arlington Street over CSX Rr. (137) is a steel continuous stringer/multi-beam or girder carrying Arlington Street over CSX Rr. (137) in Summit County, Ohio. It was built in 1969, so it is 56 years old, older than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 6,198 vehicles a day, roughly 2% of them trucks, projected to reach 8,603 by 2035. The structure is 123 ft (37.5 m) long and 56 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesArlington Street
CrossesCSX Rr. (137)
LocationNorth of Forge Street
RouteCity Street 15
StateOhio
Coordinates41.08584, -81.49038
Functional classUrban Minor Arterial

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Last inspectionFebruary 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment6: Equal to present minimum criteria
Operating rating95.3 US tons
Inventory rating57.1 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length123 ft (37.5 m)
Longest span46 ft (14 m)
Deck width56 ft (17.2 m)
Roadway width44 ft (13.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic6,198 (2015)
Projected traffic8,603 by 2035
Trucks2%
Lanes on structure4
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesRailroad
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Arlington Street over CSX Rr. (137) built?

It was built in 1969, making it 56 years old in 2025.

What condition is Arlington Street over CSX Rr. (137) in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in February 2023.

How much traffic does Arlington Street over CSX Rr. (137) carry?

About 6,198 vehicles per day (2015 count), of which roughly 2% are trucks.

How long is Arlington Street over CSX Rr. (137)?

The structure is 123 ft (37.5 m) long with a longest span of 46 ft (14 m) and a deck 56 ft wide.

Who owns Arlington Street over CSX Rr. (137)?

It is owned by the City or Municipal Highway Agency.