SR122 over Rocky Run
FairPreble County, Ohio · 1.3 MI E of Eaton · Structure no. 6802044
- Built
- 1957
- 68 years old
- Condition
- Fair
- inspected March 2024
- Type
- Slab
- Concrete Continuous
- Length
- 86 ft
- 3 main spans
- Daily traffic
- 4,864
- 2015 count
- Owner
- State
- State Highway Agency
About this bridge
SR122 over Rocky Run is a concrete continuous slab carrying SR122 over Rocky Run in Preble County, Ohio. It was built in 1957, so it is 68 years old, older than the Ohio average of 47.3 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 4,864 vehicles a day, roughly 11% of them trucks, projected to reach 6,751 by 2035. The structure is 86 ft (26.2 m) long and 40 ft wide. If it were closed, the detour would be 9.9 mi (16 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Channel and channel protection | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR122 over Rocky Run built?
It was built in 1957, making it 68 years old in 2025.
What condition is SR122 over Rocky Run in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2024.
How much traffic does SR122 over Rocky Run carry?
About 4,864 vehicles per day (2015 count), of which roughly 11% are trucks.
How long is SR122 over Rocky Run?
The structure is 86 ft (26.2 m) long with a longest span of 32 ft (9.8 m) and a deck 40 ft wide.
Who owns SR122 over Rocky Run?
It is owned by the State Highway Agency.