US Bridges

Quincy Ave over Conrail N&s Rr-Rta 24

Good

Cuyahoga County, Ohio · W. of East 105 St-Quincy · Structure no. 1869582

Built
1912
113 years old, rebuilt 2000
Condition
Good
inspected May 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
296 ft
4 main spans
Daily traffic
7,225
2015 count
Owner
City
City or Municipal Highway Agency

About this bridge

Quincy Ave over Conrail N&s Rr-Rta 24 is a steel continuous stringer/multi-beam or girder carrying Quincy Ave over Conrail N&s Rr-Rta 24 in Cuyahoga County, Ohio. It was built in 1912 and reconstructed in 2000, so it is 113 years old, older than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 7,225 vehicles a day, roughly 5% of them trucks, projected to reach 10,028 by 2035. The structure is 296 ft (90.3 m) long and 60 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesQuincy Ave
CrossesConrail N&s Rr-Rta 24
LocationW. of East 105 St-Quincy
RouteCity Street QUNCY
StateOhio
Coordinates41.49348, -81.61638
Functional classUrban Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Last inspectionMay 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment6: Equal to present minimum criteria
Operating rating51.5 US tons
Inventory rating39.7 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20 + Mod
Structure length296 ft (90.3 m)
Longest span88 ft (26.7 m)
Deck width60 ft (18.3 m)
Roadway width40 ft (12.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic7,225 (2015)
Projected traffic10,028 by 2035
Trucks5%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesRailroad
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost$464,000
NavigationNot applicable (no waterway)

Frequently asked questions

When was Quincy Ave over Conrail N&s Rr-Rta 24 built?

It was built in 1912, making it 113 years old in 2025. It was reconstructed in 2000.

What condition is Quincy Ave over Conrail N&s Rr-Rta 24 in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2024.

How much traffic does Quincy Ave over Conrail N&s Rr-Rta 24 carry?

About 7,225 vehicles per day (2015 count), of which roughly 5% are trucks.

How long is Quincy Ave over Conrail N&s Rr-Rta 24?

The structure is 296 ft (90.3 m) long with a longest span of 88 ft (26.7 m) and a deck 60 ft wide.

Who owns Quincy Ave over Conrail N&s Rr-Rta 24?

It is owned by the City or Municipal Highway Agency.