US Bridges

SR 176 Jennings Fw over Crestline Ave

Good

Cuyahoga County, Ohio · 2 MI North of IR-480 · Structure no. 1810162

Built
1997
28 years old
Condition
Good
inspected May 2023
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
161 ft
3 main spans
Daily traffic
78,054
2018 count
Owner
State
State Highway Agency

About this bridge

SR 176 Jennings Fw over Crestline Ave is a steel continuous stringer/multi-beam or girder carrying SR 176 Jennings Fw over Crestline Ave in Cuyahoga County, Ohio. It was built in 1997, so it is 28 years old, younger than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 78,054 vehicles a day, roughly 3% of them trucks, projected to reach 108,339 by 2038. The structure is 161 ft (49.1 m) long and 124 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesSR 176 Jennings Fw
CrossesCrestline Ave
Location2 MI North of IR-480
RouteState Highway 176
StateOhio
Coordinates41.44503, -81.68756
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Last inspectionMay 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment9: Superior to present desirable criteria
Operating rating55 US tons
Inventory rating42.5 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20 + Mod
Structure length161 ft (49.1 m)
Longest span61 ft (18.6 m)
Deck width124 ft (37.9 m)
Roadway width122 ft (37.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic78,054 (2018)
Projected traffic108,339 by 2038
Trucks3%
Lanes on structure6
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was SR 176 Jennings Fw over Crestline Ave built?

It was built in 1997, making it 28 years old in 2025.

What condition is SR 176 Jennings Fw over Crestline Ave in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2023.

How much traffic does SR 176 Jennings Fw over Crestline Ave carry?

About 78,054 vehicles per day (2018 count), of which roughly 3% are trucks.

How long is SR 176 Jennings Fw over Crestline Ave?

The structure is 161 ft (49.1 m) long with a longest span of 61 ft (18.6 m) and a deck 124 ft wide.

Who owns SR 176 Jennings Fw over Crestline Ave?

It is owned by the State Highway Agency.