US Bridges

S.R.7 over Deep Run and CO RD 2

Fair

Belmont County, Ohio · 0.53 Mi.S.Of Jef.Co.Line · Structure no. 0700827

Built
1976
49 years old
Condition
Fair
inspected April 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
137 ft
3 main spans
Daily traffic
18,497
2015 count
Owner
State
State Highway Agency

About this bridge

S.R.7 over Deep Run and CO RD 2 is a steel continuous stringer/multi-beam or girder carrying S.R.7 over Deep Run and CO RD 2 in Belmont County, Ohio. It was built in 1976, so it is 49 years old, older than the Ohio average of 47.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 18,497 vehicles a day, roughly 11% of them trucks, projected to reach 25,674 by 2035. The structure is 137 ft (41.8 m) long and 75 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesS.R.7
CrossesDeep Run and CO RD 2
Location0.53 Mi.S.Of Jef.Co.Line
RouteState Highway 7
StateOhio
Coordinates40.14986, -80.71283
Functional classUrban Other Principal Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure7 GoodSome minor problems.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionApril 2024
Inspection intervalevery 12 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation6: Equal to present minimum criteria
Deck geometry9: Superior to present desirable criteria
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating47.5 US tons
Inventory rating36.4 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20 + Mod
Structure length137 ft (41.8 m)
Longest span55 ft (16.8 m)
Deck width75 ft (23 m)
Roadway width69 ft (21 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic18,497 (2015)
Projected traffic25,674 by 2035
Trucks11%
Lanes on structure4
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway and waterway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was S.R.7 over Deep Run and CO RD 2 built?

It was built in 1976, making it 49 years old in 2025.

What condition is S.R.7 over Deep Run and CO RD 2 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in April 2024.

How much traffic does S.R.7 over Deep Run and CO RD 2 carry?

About 18,497 vehicles per day (2015 count), of which roughly 11% are trucks.

How long is S.R.7 over Deep Run and CO RD 2?

The structure is 137 ft (41.8 m) long with a longest span of 55 ft (16.8 m) and a deck 75 ft wide.

Who owns S.R.7 over Deep Run and CO RD 2?

It is owned by the State Highway Agency.