US Bridges

Rynex Corners RD over 90IX RTE I90

Good

Schenectady County, New York · Int Rynex Corners Rd& I90 · Structure no. 000000005513760

Built
2001
24 years old
Condition
Good
inspected October 2023
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
218 ft
2 main spans
Daily traffic
516
2020 count
Owner
Toll Authority
State Toll Authority

About this bridge

Rynex Corners RD over 90IX RTE I90 is a steel continuous stringer/multi-beam or girder carrying Rynex Corners RD over 90IX RTE I90 in Schenectady County, New York. It was built in 2001, so it is 24 years old, younger than the New York average of 53 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 516 vehicles a day, roughly 8% of them trucks, projected to reach 722 by 2040. The structure is 218 ft (66.4 m) long and 31 ft wide. If it were closed, the detour would be 5 mi (8 km).

CarriesRynex Corners RD
Crosses90IX RTE I90
LocationInt Rynex Corners Rd& I90
RouteCounty Highway 0
Coordinates42.88687, -74.07852
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure9 ExcellentNo problems noted.
Last inspectionOctober 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating99 US tons
Inventory rating85 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadHS 25 or greater
Structure length218 ft (66.4 m)
Longest span125 ft (38.1 m)
Deck width31 ft (9.5 m)
Roadway width29 ft (8.7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic516 (2020)
Projected traffic722 by 2040
Trucks8%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed5 mi (8 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Toll Authority
Maintained byState Toll Authority
Historic statusNot eligible for the National Register of Historic Places
Work proposedWidening with deck rehabilitation or replacement
Estimated improvement cost$2.5 million (2024 estimate)
NavigationNot applicable (no waterway)

Frequently asked questions

When was Rynex Corners RD over 90IX RTE I90 built?

It was built in 2001, making it 24 years old in 2025.

What condition is Rynex Corners RD over 90IX RTE I90 in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in October 2023.

How much traffic does Rynex Corners RD over 90IX RTE I90 carry?

About 516 vehicles per day (2020 count), of which roughly 8% are trucks.

How long is Rynex Corners RD over 90IX RTE I90?

The structure is 218 ft (66.4 m) long with a longest span of 125 ft (38.1 m) and a deck 31 ft wide.

Who owns Rynex Corners RD over 90IX RTE I90?

It is owned by the State Toll Authority.