RTE I84 over RTE 6
PoorOrange County, New York · 3.2 MI E I84 Int 1 · Structure no. 000000001003082
- Built
- 1964
- 61 years old, rebuilt 2006
- Condition
- Poor
- inspected April 2024
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 153 ft
- 3 main spans
- Daily traffic
- 14,281
- 2019 count
- Owner
- State
- State Highway Agency
About this bridge
RTE I84 over RTE 6 is a steel stringer/multi-beam or girder carrying RTE I84 over RTE 6 in Orange County, New York. It was built in 1964 and reconstructed in 2006, so it is 61 years old, older than the New York average of 53 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 14,281 vehicles a day, roughly 24% of them trucks, projected to reach 25,035 by 2041. The structure is 153 ft (46.6 m) long and 41 ft wide. If it were closed, the detour would be 0.6 mi (1 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was RTE I84 over RTE 6 built?
It was built in 1964, making it 61 years old in 2025. It was reconstructed in 2006.
What condition is RTE I84 over RTE 6 in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in April 2024.
How much traffic does RTE I84 over RTE 6 carry?
About 14,281 vehicles per day (2019 count), of which roughly 24% are trucks.
How long is RTE I84 over RTE 6?
The structure is 153 ft (46.6 m) long with a longest span of 54 ft (16.4 m) and a deck 41 ft wide.
Who owns RTE I84 over RTE 6?
It is owned by the State Highway Agency.