RTE I90 over William ST
FairErie County, New York · 3.4 MI S JCT I90 <rte 130 · Structure no. 000000005512069
- Built
- 1953
- 72 years old, rebuilt 1973
- Condition
- Fair
- inspected October 2023
- Type
- Stringer/Multi-beam or Girder
- Steel Continuous
- Length
- 145 ft
- 3 main spans
- Daily traffic
- 114,760
- 2019 count
- Owner
- Toll Authority
- State Toll Authority
About this bridge
RTE I90 over William ST is a steel continuous stringer/multi-beam or girder carrying RTE I90 over William ST in Erie County, New York. It was built in 1953 and reconstructed in 1973, so it is 72 years old, older than the New York average of 53 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 114,760 vehicles a day, roughly 10% of them trucks, projected to reach 128,611 by 2041. The structure is 145 ft (44.1 m) long and 113 ft wide. If it were closed, the detour would be 1.9 mi (3 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was RTE I90 over William ST built?
It was built in 1953, making it 72 years old in 2025. It was reconstructed in 1973.
What condition is RTE I90 over William ST in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in October 2023.
How much traffic does RTE I90 over William ST carry?
About 114,760 vehicles per day (2019 count), of which roughly 10% are trucks.
How long is RTE I90 over William ST?
The structure is 145 ft (44.1 m) long with a longest span of 67 ft (20.4 m) and a deck 113 ft wide.
Who owns RTE I90 over William ST?
It is owned by the State Toll Authority.