RTE 952W over 86I 17 51123127 RTE I86
FairCattaraugus County, New York · At Int I86 & Rt 952W · Structure no. 000000001092010
- Built
- 1973
- 52 years old
- Condition
- Fair
- inspected May 2024
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 290 ft
- 2 main spans
- Daily traffic
- 4,032
- 2020 count
- Owner
- State
- State Highway Agency
About this bridge
RTE 952W over 86I 17 51123127 RTE I86 is a steel stringer/multi-beam or girder carrying RTE 952W over 86I 17 51123127 RTE I86 in Cattaraugus County, New York. It was built in 1973, so it is 52 years old, younger than the New York average of 53 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 4,032 vehicles a day, roughly 13% of them trucks, projected to reach 4,988 by 2041. The structure is 290 ft (88.4 m) long and 66 ft wide. If it were closed, the detour would be 0.6 mi (1 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 7 Good | Some minor problems. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was RTE 952W over 86I 17 51123127 RTE I86 built?
It was built in 1973, making it 52 years old in 2025.
What condition is RTE 952W over 86I 17 51123127 RTE I86 in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in May 2024.
How much traffic does RTE 952W over 86I 17 51123127 RTE I86 carry?
About 4,032 vehicles per day (2020 count), of which roughly 13% are trucks.
How long is RTE 952W over 86I 17 51123127 RTE I86?
The structure is 290 ft (88.4 m) long with a longest span of 143 ft (43.5 m) and a deck 66 ft wide.
Who owns RTE 952W over 86I 17 51123127 RTE I86?
It is owned by the State Highway Agency.