RTE 7 over 787I 787I 1101 4004 RTE
FairAlbany County, New York · JCT Alt Rt 7 & I787 · Structure no. 000000001092269
- Built
- 1971
- 54 years old
- Condition
- Fair
- inspected November 2024
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 170 ft
- 1 main span
- Daily traffic
- 63,101
- 2020 count
- Owner
- State
- State Highway Agency
About this bridge
RTE 7 over 787I 787I 1101 4004 RTE is a steel stringer/multi-beam or girder carrying RTE 7 over 787I 787I 1101 4004 RTE in Albany County, New York. It was built in 1971, so it is 54 years old, older than the New York average of 53 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 63,101 vehicles a day, roughly 8% of them trucks, projected to reach 73,121 by 2041. The structure is 170 ft (51.8 m) long and 158 ft wide. If it were closed, the detour would be 0.6 mi (1 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was RTE 7 over 787I 787I 1101 4004 RTE built?
It was built in 1971, making it 54 years old in 2025.
What condition is RTE 7 over 787I 787I 1101 4004 RTE in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in November 2024.
How much traffic does RTE 7 over 787I 787I 1101 4004 RTE carry?
About 63,101 vehicles per day (2020 count), of which roughly 8% are trucks.
How long is RTE 7 over 787I 787I 1101 4004 RTE?
The structure is 170 ft (51.8 m) long with a longest span of 167 ft (50.9 m) and a deck 158 ft wide.
Who owns RTE 7 over 787I 787I 1101 4004 RTE?