US Bridges

SR2130 over I95

PoorPosted for load

Johnston County, North Carolina · 0.2 Mi. W. Jct. SR2335 · Structure no. 000000001010110

Built
1956
69 years old
Condition
Poor
inspected December 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
175 ft
4 main spans
Daily traffic
1,800
2022 count
Owner
State
State Highway Agency

About this bridge

SR2130 over I95 is a steel stringer/multi-beam or girder carrying SR2130 over I95 in Johnston County, North Carolina. It was built in 1956, so it is 69 years old, older than the North Carolina average of 38.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: posted for load restriction.

It carries about 1,800 vehicles a day, roughly 6% of them trucks, projected to reach 3,600 by 2040. The structure is 175 ft (53.3 m) long and 31 ft wide. If it were closed, the detour would be 0.6 mi (1 km).

CarriesSR2130
CrossesI95
Location0.2 Mi. W. Jct. SR2335
RouteState Highway 2130
Coordinates35.55656, -78.20094
Functional classRural Local

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionDecember 2024
Inspection intervalevery 24 months
Operating statusPosted for load restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating37.9 US tons
Inventory rating22.9 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans4
Design loadHS 15
Structure length175 ft (53.3 m)
Longest span52 ft (15.8 m)
Deck width31 ft (9.6 m)
Roadway width26 ft (7.9 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic1,800 (2022)
Projected traffic3,600 by 2040
Trucks6%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesOverpass structure at an interchange
CrossesHighway
Detour if closed0.6 mi (1 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was SR2130 over I95 built?

It was built in 1956, making it 69 years old in 2025.

What condition is SR2130 over I95 in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in December 2024.

How much traffic does SR2130 over I95 carry?

About 1,800 vehicles per day (2022 count), of which roughly 6% are trucks.

How long is SR2130 over I95?

The structure is 175 ft (53.3 m) long with a longest span of 52 ft (15.8 m) and a deck 31 ft wide.

Who owns SR2130 over I95?

It is owned by the State Highway Agency.