Pvt Private Drive over Drainage Ditch
FairPosted for loadMcDonald County, Missouri · S 28 T 21 N R 34 W · Structure no. 36502
- Built
- 1950
- 75 years old
- Condition
- Fair
- inspected October 2024
- Type
- Stringer/Multi-beam or Girder
- Wood or Timber
- Length
- 21 ft
- 1 main span
- Daily traffic
- 20
- 2024 count
- Owner
- State
- State Highway Agency
About this bridge
Pvt Private Drive over Drainage Ditch is a wood or timber stringer/multi-beam or girder carrying Pvt Private Drive over Drainage Ditch in McDonald County, Missouri. It was built in 1950, so it is 75 years old, older than the Missouri average of 45.1 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.
It carries about 20 vehicles a day, roughly 10% of them trucks, projected to reach 35 by 2044. The structure is 21 ft (6.4 m) long and 15 ft wide. If it were closed, the detour would be 98.8 mi (159 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 8 Very Good | No problems noted. |
| Channel and channel protection | 9 Excellent | No problems noted. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was Pvt Private Drive over Drainage Ditch built?
It was built in 1950, making it 75 years old in 2025.
What condition is Pvt Private Drive over Drainage Ditch in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in October 2024.
How much traffic does Pvt Private Drive over Drainage Ditch carry?
About 20 vehicles per day (2024 count), of which roughly 10% are trucks.
How long is Pvt Private Drive over Drainage Ditch?
The structure is 21 ft (6.4 m) long with a longest span of 19 ft (5.8 m) and a deck 15 ft wide.
Who owns Pvt Private Drive over Drainage Ditch?
It is owned by the State Highway Agency.