US Bridges

E Concord ST over Bracken Br

FairPosted for load

Harrison County, Missouri · S 28 T 66 N R 28 W · Structure no. 15994

Built
1968
57 years old
Condition
Fair
inspected January 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
30 ft
1 main span
Daily traffic
35
2024 count
Owner
County
County Highway Agency

About this bridge

E Concord ST over Bracken Br is a steel stringer/multi-beam or girder carrying E Concord ST over Bracken Br in Harrison County, Missouri. It was built in 1968, so it is 57 years old, older than the Missouri average of 45.1 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.

It carries about 35 vehicles a day, roughly 10% of them trucks, projected to reach 40 by 2044. The structure is 30 ft (9.1 m) long and 14 ft wide. If it were closed, the detour would be 3.7 mi (6 km).

CarriesE Concord ST
CrossesBracken Br
LocationS 28 T 66 N R 28 W
RouteCounty Highway 106
Coordinates40.49322, -93.95738
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Channel and channel protection5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionJanuary 2024
Inspection intervalevery 24 months
Operating statusPosted for load restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry6: Equal to present minimum criteria
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating20.8 US tons
Inventory rating12.9 US tons

Structure

MaterialSteel
DeckWood or timber
Main spans1
Design loadH 10
Structure length30 ft (9.1 m)
Longest span28 ft (8.5 m)
Deck width14 ft (4.3 m)
Roadway width14 ft (4.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic35 (2024)
Projected traffic40 by 2044
Trucks10%
Lanes on structure1
Traffic directionOne-lane bridge for two-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.7 mi (6 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCounty Highway Agency
Maintained byCounty Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was E Concord ST over Bracken Br built?

It was built in 1968, making it 57 years old in 2025.

What condition is E Concord ST over Bracken Br in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in January 2024.

How much traffic does E Concord ST over Bracken Br carry?

About 35 vehicles per day (2024 count), of which roughly 10% are trucks.

How long is E Concord ST over Bracken Br?

The structure is 30 ft (9.1 m) long with a longest span of 28 ft (8.5 m) and a deck 14 ft wide.

Who owns E Concord ST over Bracken Br?

It is owned by the County Highway Agency.