LA0182 over Sandager Canal
PoorPosted for loadIberia Parish, Louisiana · 2.5 MI SE of LA 320 · Structure no. 032300040506771
- Built
- 1930
- 95 years old
- Condition
- Poor
- inspected May 2023
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 64 ft
- 3 main spans
- Daily traffic
- 6,242
- 2021 count
- Owner
- State
- State Highway Agency
About this bridge
LA0182 over Sandager Canal is a steel stringer/multi-beam or girder carrying LA0182 over Sandager Canal in Iberia Parish, Louisiana. It was built in 1930, so it is 95 years old, older than the Louisiana average of 43 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: posted for load restriction.
It carries about 6,242 vehicles a day, roughly 9% of them trucks, projected to reach 6,866 by 2041. The structure is 64 ft (19.5 m) long and 26 ft wide. If it were closed, the detour would be 1.2 mi (2 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Channel and channel protection | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was LA0182 over Sandager Canal built?
It was built in 1930, making it 95 years old in 2025.
What condition is LA0182 over Sandager Canal in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in May 2023.
How much traffic does LA0182 over Sandager Canal carry?
About 6,242 vehicles per day (2021 count), of which roughly 9% are trucks.
How long is LA0182 over Sandager Canal?
The structure is 64 ft (19.5 m) long with a longest span of 21 ft (6.4 m) and a deck 26 ft wide.
Who owns LA0182 over Sandager Canal?
It is owned by the State Highway Agency.