US Bridges

Picard RD over Dinde Bayou

PoorPosted for load

Calcasieu Parish, Louisiana · 0.3 MI N of W. Parish RD · Structure no. 071030137932331

Built
1968
57 years old
Condition
Poor
inspected May 2024
Type
Slab
Concrete
Length
57 ft
3 main spans
Daily traffic
2,741
2021 count
Owner
City
City or Municipal Highway Agency

About this bridge

Picard RD over Dinde Bayou is a concrete slab carrying Picard RD over Dinde Bayou in Calcasieu Parish, Louisiana. It was built in 1968, so it is 57 years old, older than the Louisiana average of 43 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 3 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: posted for load restriction.

It carries about 2,741 vehicles a day, projected to reach 3,015 by 2041. The structure is 57 ft (17.4 m) long and 35 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesPicard RD
CrossesDinde Bayou
Location0.3 MI N of W. Parish RD
RouteCounty Highway 0
Coordinates30.22769, -93.3849
Functional classUrban Local

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck4 PoorAdvanced section loss, deterioration, spalling or scour.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure3 SeriousLoss of section, deterioration, spalling or scour have seriously affected primary structural components.
Channel and channel protection7 GoodSome minor problems.
Last inspectionMay 2024
Inspection intervalevery 12 months
Operating statusPosted for load restriction
ScourFoundations stable; scour above top of footing
Structural evaluation3: Basically intolerable, requiring high priority of corrective action
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment5: Somewhat better than minimum adequacy to tolerate being left in place as is
Operating rating35.7 US tons
Inventory rating27.4 US tons

Structure

Structure typeSlab
MaterialConcrete
DeckConcrete, precast panels
Main spans3
Design loadHS 20
Structure length57 ft (17.4 m)
Longest span19 ft (5.8 m)
Deck width35 ft (10.8 m)
Roadway width28 ft (8.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic2,741 (2021)
Projected traffic3,015 by 2041
Trucks—
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Picard RD over Dinde Bayou built?

It was built in 1968, making it 57 years old in 2025.

What condition is Picard RD over Dinde Bayou in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in May 2024.

How much traffic does Picard RD over Dinde Bayou carry?

About 2,741 vehicles per day (2021 count).

How long is Picard RD over Dinde Bayou?

The structure is 57 ft (17.4 m) long with a longest span of 19 ft (5.8 m) and a deck 35 ft wide.

Who owns Picard RD over Dinde Bayou?

It is owned by the City or Municipal Highway Agency.