US Bridges

I0020 over St. Louis & SW RR

Poor

Caddo Parish, Louisiana · .2 MI East of LA 1 · Structure no. 040904510119331

Built
1965
60 years old
Condition
Poor
inspected July 2023
Type
Girder and Floorbeam System
Steel Continuous
Length
365 ft
3 main spans
Daily traffic
84,672
2018 count
Owner
State
State Highway Agency

About this bridge

I0020 over St. Louis & SW RR is a steel continuous girder and floorbeam system carrying I0020 over St. Louis & SW RR in Caddo Parish, Louisiana. It was built in 1965, so it is 60 years old, older than the Louisiana average of 43 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

It carries about 84,672 vehicles a day, roughly 19% of them trucks, projected to reach 93,139 by 2038. The structure is 365 ft (111.3 m) long and 89 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesI0020
CrossesSt. Louis & SW RR
Location.2 MI East of LA 1
RouteInterstate 20
Coordinates32.51121, -93.7407
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionJuly 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation2: Basically intolerable, requiring high priority of replacement
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating21.8 US tons
Inventory rating16.8 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length365 ft (111.3 m)
Longest span130 ft (39.6 m)
Deck width89 ft (27.2 m)
Roadway width79 ft (24.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic84,672 (2018)
Projected traffic93,139 by 2038
Trucks19%
Lanes on structure6
Traffic directionTwo-way traffic
CarriesOverpass structure at an interchange
CrossesHighway and railroad
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$3.1 million
NavigationNot applicable (no waterway)

Frequently asked questions

When was I0020 over St. Louis & SW RR built?

It was built in 1965, making it 60 years old in 2025.

What condition is I0020 over St. Louis & SW RR in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in July 2023.

How much traffic does I0020 over St. Louis & SW RR carry?

About 84,672 vehicles per day (2018 count), of which roughly 19% are trucks.

How long is I0020 over St. Louis & SW RR?

The structure is 365 ft (111.3 m) long with a longest span of 130 ft (39.6 m) and a deck 89 ft wide.

Who owns I0020 over St. Louis & SW RR?

It is owned by the State Highway Agency.