LA0110 over Drain
PoorBeauregard Parish, Louisiana · 1.2 MI S of US 190 · Structure no. 070601900100921
- Built
- 1968
- 57 years old
- Condition
- Poor
- inspected August 2024
- Type
- Slab
- Concrete
- Length
- 39 ft
- 2 main spans
- Daily traffic
- 1,947
- 2021 count
- Owner
- State
- State Highway Agency
About this bridge
LA0110 over Drain is a concrete slab carrying LA0110 over Drain in Beauregard Parish, Louisiana. It was built in 1968, so it is 57 years old, older than the Louisiana average of 43 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 1,947 vehicles a day, roughly 17% of them trucks, projected to reach 2,141 by 2041. The structure is 39 ft (11.9 m) long and 31 ft wide. If it were closed, the detour would be 23 mi (37 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Channel and channel protection | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was LA0110 over Drain built?
It was built in 1968, making it 57 years old in 2025.
What condition is LA0110 over Drain in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in August 2024.
How much traffic does LA0110 over Drain carry?
About 1,947 vehicles per day (2021 count), of which roughly 17% are trucks.
How long is LA0110 over Drain?
The structure is 39 ft (11.9 m) long with a longest span of 19 ft (5.8 m) and a deck 31 ft wide.
Who owns LA0110 over Drain?
It is owned by the State Highway Agency.