US Bridges

I-465 SB & Cd over US 40 Eb/Wb & Cd

Good

Marion County, Indiana · 01.15 S US 36 · Structure no. 076648

Built
2010
15 years old
Condition
Good
inspected June 2024
Type
Tee Beam
Prestressed Concrete Continuous
Length
191 ft
2 main spans
Daily traffic
71,031
2021 count
Owner
State
State Highway Agency

About this bridge

I-465 SB & Cd over US 40 Eb/Wb & Cd is a prestressed concrete continuous tee beam carrying I-465 SB & Cd over US 40 Eb/Wb & Cd in Marion County, Indiana. It was built in 2010, so it is 15 years old, younger than the Indiana average of 46.6 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 71,031 vehicles a day, roughly 18% of them trucks, projected to reach 92,500 by 2029. The structure is 191 ft (58.2 m) long and 111 ft wide. If it were closed, the detour would be 0.6 mi (1 km).

CarriesI-465 SB & Cd
CrossesUS 40 Eb/Wb & Cd
Location01.15 S US 36
RouteInterstate 465
StateIndiana
Coordinates39.74833, -86.26485
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Last inspectionJune 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating70.8 US tons
Inventory rating42.1 US tons

Structure

Structure typeTee Beam
MaterialPrestressed Concrete Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadHS 25 or greater
Structure length191 ft (58.2 m)
Longest span107 ft (32.6 m)
Deck width111 ft (33.9 m)
Roadway width106 ft (32.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic71,031 (2021)
Projected traffic92,500 by 2029
Trucks18%
Lanes on structure4
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed0.6 mi (1 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was I-465 SB & Cd over US 40 Eb/Wb & Cd built?

It was built in 2010, making it 15 years old in 2025.

What condition is I-465 SB & Cd over US 40 Eb/Wb & Cd in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in June 2024.

How much traffic does I-465 SB & Cd over US 40 Eb/Wb & Cd carry?

About 71,031 vehicles per day (2021 count), of which roughly 18% are trucks.

How long is I-465 SB & Cd over US 40 Eb/Wb & Cd?

The structure is 191 ft (58.2 m) long with a longest span of 107 ft (32.6 m) and a deck 111 ft wide.

Who owns I-465 SB & Cd over US 40 Eb/Wb & Cd?

It is owned by the State Highway Agency.