US Bridges

Sbi 10 (fas 1532) over I-72

Poor

Piatt County, Illinois · W of White Heath · Structure no. 074002600000000

Built
1962
63 years old
Condition
Poor
inspected November 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
281 ft
4 main spans
Daily traffic
925
2020 count
Owner
State
State Highway Agency

About this bridge

Sbi 10 (fas 1532) over I-72 is a steel continuous stringer/multi-beam or girder carrying Sbi 10 (fas 1532) over I-72 in Piatt County, Illinois. It was built in 1962, so it is 63 years old, older than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 3 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: open, would be posted or closed except for temporary shoring.

It carries about 925 vehicles a day, roughly 3% of them trucks, projected to reach 934 by 2046. The structure is 281 ft (85.6 m) long and 34 ft wide.

CarriesSbi 10 (fas 1532)
CrossesI-72
LocationW of White Heath
RouteCounty Highway 0
Coordinates40.08313, -88.52605
Functional classRural Major Collector

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck4 PoorAdvanced section loss, deterioration, spalling or scour.
Superstructure3 SeriousLoss of section, deterioration, spalling or scour have seriously affected primary structural components.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionNovember 2024
Inspection intervalevery 12 months
Operating statusOpen, would be posted or closed except for temporary shoring
ScourBridge not over waterway
Structural evaluation3: Basically intolerable, requiring high priority of corrective action
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment7: Better than present minimum criteria
Operating rating22.2 US tons
Inventory rating13.2 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20 + Mod
Structure length281 ft (85.6 m)
Longest span87 ft (26.5 m)
Deck width34 ft (10.3 m)
Roadway width28 ft (8.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic925 (2020)
Projected traffic934 by 2046
Trucks3%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesOverpass structure at an interchange
CrossesHighway
Detour if closed—
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Sbi 10 (fas 1532) over I-72 built?

It was built in 1962, making it 63 years old in 2025.

What condition is Sbi 10 (fas 1532) over I-72 in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in November 2024.

How much traffic does Sbi 10 (fas 1532) over I-72 carry?

About 925 vehicles per day (2020 count), of which roughly 3% are trucks.

How long is Sbi 10 (fas 1532) over I-72?

The structure is 281 ft (85.6 m) long with a longest span of 87 ft (26.5 m) and a deck 34 ft wide.

Who owns Sbi 10 (fas 1532) over I-72?

It is owned by the State Highway Agency.