US Bridges

TR 83 over Hardin Ditch

Fair

Mason County, Illinois · 3 MI Nnw Easton · Structure no. 063350100000000

Built
1976
49 years old
Condition
Fair
inspected March 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
60 ft
1 main span
Daily traffic
50
2024 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

TR 83 over Hardin Ditch is a prestressed concrete box beam or girders - multiple carrying TR 83 over Hardin Ditch in Mason County, Illinois. It was built in 1976, so it is 49 years old, older than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 50 vehicles a day, projected to reach 51 by 2046. The structure is 60 ft (18.3 m) long and 26 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesTR 83
CrossesHardin Ditch
Location3 MI Nnw Easton
RouteCounty Highway 0
Coordinates40.27479, -89.85518
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure7 GoodSome minor problems.
Channel and channel protection7 GoodSome minor problems.
Last inspectionMarch 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Waterway adequacy7: Better than present minimum criteria
Approach roadway alignment6: Equal to present minimum criteria
Operating rating40.7 US tons
Inventory rating24.7 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans1
Design loadHS 15
Structure length60 ft (18.3 m)
Longest span58 ft (17.7 m)
Deck width26 ft (8 m)
Roadway width24 ft (7.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic50 (2024)
Projected traffic51 by 2046
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was TR 83 over Hardin Ditch built?

It was built in 1976, making it 49 years old in 2025.

What condition is TR 83 over Hardin Ditch in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2023.

How much traffic does TR 83 over Hardin Ditch carry?

About 50 vehicles per day (2024 count).

How long is TR 83 over Hardin Ditch?

The structure is 60 ft (18.3 m) long with a longest span of 58 ft (17.7 m) and a deck 26 ft wide.

Who owns TR 83 over Hardin Ditch?

It is owned by the Town or Township Highway Agency.