Seneca ST#2300 over Stream
PoorLaSalle County, Illinois · N 2553 E 2890 · Structure no. 050305000000000
- Built
- 1965
- 60 years old
- Condition
- Poor
- inspected June 2023
- Type
- Box Beam or Girders - Multiple
- Prestressed Concrete
- Length
- 48 ft
- 1 main span
- Daily traffic
- 1,600
- 2020 count
- Owner
- City
- City or Municipal Highway Agency
About this bridge
Seneca ST#2300 over Stream is a prestressed concrete box beam or girders - multiple carrying Seneca ST#2300 over Stream in LaSalle County, Illinois. It was built in 1965, so it is 60 years old, older than the Illinois average of 45.3 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 1,600 vehicles a day, roughly 8% of them trucks, projected to reach 1,616 by 2046. The structure is 48 ft (14.6 m) long and 27 ft wide.
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Superstructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Substructure | 7 Good | Some minor problems. |
| Channel and channel protection | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was Seneca ST#2300 over Stream built?
It was built in 1965, making it 60 years old in 2025.
What condition is Seneca ST#2300 over Stream in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in June 2023.
How much traffic does Seneca ST#2300 over Stream carry?
About 1,600 vehicles per day (2020 count), of which roughly 8% are trucks.
How long is Seneca ST#2300 over Stream?
The structure is 48 ft (14.6 m) long with a longest span of 48 ft (14.6 m) and a deck 27 ft wide.
Who owns Seneca ST#2300 over Stream?
It is owned by the City or Municipal Highway Agency.