US Bridges

TR 113 over Trib. So. Hendn Cr.

Fair

Henderson County, Illinois · SW-12-T10NR4W · Structure no. 036423500000000

Built
2002
23 years old
Condition
Fair
inspected February 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
132 ft
3 main spans
Daily traffic
50
2021 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

TR 113 over Trib. So. Hendn Cr. is a prestressed concrete box beam or girders - multiple carrying TR 113 over Trib. So. Hendn Cr. in Henderson County, Illinois. It was built in 2002, so it is 23 years old, younger than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 50 vehicles a day, projected to reach 51 by 2046. The structure is 132 ft (40.1 m) long and 24 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesTR 113
CrossesTrib. So. Hendn Cr.
LocationSW-12-T10NR4W
RouteCounty Highway 0
Coordinates40.86501, -90.80362
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection7 GoodSome minor problems.
Last inspectionFebruary 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating48.6 US tons
Inventory rating35.7 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans3
Design loadHS 20
Structure length132 ft (40.1 m)
Longest span50 ft (15.1 m)
Deck width24 ft (7.3 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic50 (2021)
Projected traffic51 by 2046
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was TR 113 over Trib. So. Hendn Cr. built?

It was built in 2002, making it 23 years old in 2025.

What condition is TR 113 over Trib. So. Hendn Cr. in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in February 2023.

How much traffic does TR 113 over Trib. So. Hendn Cr. carry?

About 50 vehicles per day (2021 count).

How long is TR 113 over Trib. So. Hendn Cr.?

The structure is 132 ft (40.1 m) long with a longest span of 50 ft (15.1 m) and a deck 24 ft wide.

Who owns TR 113 over Trib. So. Hendn Cr.?

It is owned by the Town or Township Highway Agency.