US Bridges

TR 99 over Carlton Branch

Good

Franklin County, Illinois · East Heard Road · Structure no. 028336400000000

Built
2001
24 years old
Condition
Good
inspected May 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
29 ft
1 main span
Daily traffic
35
2024 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

TR 99 over Carlton Branch is a prestressed concrete box beam or girders - multiple carrying TR 99 over Carlton Branch in Franklin County, Illinois. It was built in 2001, so it is 24 years old, younger than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 35 vehicles a day, roughly 51% of them trucks, projected to reach 25 by 2046. The structure is 29 ft (8.9 m) long and 24 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesTR 99
CrossesCarlton Branch
LocationEast Heard Road
RouteCounty Highway 0
Coordinates38.06449, -88.73303
Functional classRural Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionMay 2024
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry6: Equal to present minimum criteria
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating48.6 US tons
Inventory rating35.7 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans1
Design loadHS 20
Structure length29 ft (8.9 m)
Longest span27 ft (8.2 m)
Deck width24 ft (7.3 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic35 (2024)
Projected traffic25 by 2046
Trucks51%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was TR 99 over Carlton Branch built?

It was built in 2001, making it 24 years old in 2025.

What condition is TR 99 over Carlton Branch in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2024.

How much traffic does TR 99 over Carlton Branch carry?

About 35 vehicles per day (2024 count), of which roughly 51% are trucks.

How long is TR 99 over Carlton Branch?

The structure is 29 ft (8.9 m) long with a longest span of 27 ft (8.2 m) and a deck 24 ft wide.

Who owns TR 99 over Carlton Branch?

It is owned by the Town or Township Highway Agency.