US Bridges

FAP 116 (il 130) over CSXT RR

Fair

Cumberland County, Illinois · .5 MI S US 40 · Structure no. 018002600000000

Built
1931
94 years old, rebuilt 1980
Condition
Fair
inspected May 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
128 ft
3 main spans
Daily traffic
3,150
2023 count
Owner
State
State Highway Agency

About this bridge

FAP 116 (il 130) over CSXT RR is a steel stringer/multi-beam or girder carrying FAP 116 (il 130) over CSXT RR in Cumberland County, Illinois. It was built in 1931 and reconstructed in 1980, so it is 94 years old, older than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 3,150 vehicles a day, roughly 18% of them trucks, projected to reach 3,328 by 2046. The structure is 128 ft (39 m) long and 35 ft wide.

CarriesFAP 116 (il 130)
CrossesCSXT RR
Location.5 MI S US 40
RouteState Highway 130
Coordinates39.24266, -88.15499
Functional classRural Minor Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionMay 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating59.6 US tons
Inventory rating36.8 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length128 ft (39 m)
Longest span45 ft (13.7 m)
Deck width35 ft (10.7 m)
Roadway width32 ft (9.8 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,150 (2023)
Projected traffic3,328 by 2046
Trucks18%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesRailroad
Detour if closed—
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was FAP 116 (il 130) over CSXT RR built?

It was built in 1931, making it 94 years old in 2025. It was reconstructed in 1980.

What condition is FAP 116 (il 130) over CSXT RR in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in May 2023.

How much traffic does FAP 116 (il 130) over CSXT RR carry?

About 3,150 vehicles per day (2023 count), of which roughly 18% are trucks.

How long is FAP 116 (il 130) over CSXT RR?

The structure is 128 ft (39 m) long with a longest span of 45 ft (13.7 m) and a deck 35 ft wide.

Who owns FAP 116 (il 130) over CSXT RR?

It is owned by the State Highway Agency.