Scott Ave over Union Pacific RR
FairCook County, Illinois · 0.08M Ne.Green Bay R · Structure no. 016704000000000
- Built
- 1940
- 85 years old, rebuilt 1990
- Condition
- Fair
- inspected July 2023
- Type
- Stringer/Multi-beam or Girder
- Steel Continuous
- Length
- 157 ft
- 4 main spans
- Daily traffic
- 1,850
- 2022 count
- Owner
- City
- City or Municipal Highway Agency
About this bridge
Scott Ave over Union Pacific RR is a steel continuous stringer/multi-beam or girder carrying Scott Ave over Union Pacific RR in Cook County, Illinois. It was built in 1940 and reconstructed in 1990, so it is 85 years old, older than the Illinois average of 45.3 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 1,850 vehicles a day, roughly 16% of them trucks, projected to reach 1,818 by 2046. The structure is 157 ft (47.9 m) long and 50 ft wide. If it were closed, the detour would be 1.2 mi (2 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was Scott Ave over Union Pacific RR built?
It was built in 1940, making it 85 years old in 2025. It was reconstructed in 1990.
What condition is Scott Ave over Union Pacific RR in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2023.
How much traffic does Scott Ave over Union Pacific RR carry?
About 1,850 vehicles per day (2022 count), of which roughly 16% are trucks.
How long is Scott Ave over Union Pacific RR?
The structure is 157 ft (47.9 m) long with a longest span of 45 ft (13.7 m) and a deck 50 ft wide.
Who owns Scott Ave over Union Pacific RR?
It is owned by the City or Municipal Highway Agency.