US Bridges

Andrews Dr. over US 40 and CSX RR

Good

Bond County, Illinois · 1.00 MI E Il 127 · Structure no. 003600000000000

Built
2011
14 years old
Condition
Good
inspected January 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
347 ft
2 main spans
Daily traffic
225
2020 count
Owner
City
City or Municipal Highway Agency

About this bridge

Andrews Dr. over US 40 and CSX RR is a steel continuous stringer/multi-beam or girder carrying Andrews Dr. over US 40 and CSX RR in Bond County, Illinois. It was built in 2011, so it is 14 years old, younger than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 225 vehicles a day, roughly 21% of them trucks, projected to reach 227 by 2046. The structure is 347 ft (105.7 m) long and 35 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesAndrews Dr.
CrossesUS 40 and CSX RR
Location1.00 MI E Il 127
RouteCity Street 0
Coordinates38.88594, -89.37403
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Last inspectionJanuary 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation8: Equal to present desirable criteria
Deck geometry7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating73.5 US tons
Inventory rating44 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadHS 20
Structure length347 ft (105.7 m)
Longest span170 ft (51.8 m)
Deck width35 ft (10.7 m)
Roadway width32 ft (9.8 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic225 (2020)
Projected traffic227 by 2046
Trucks21%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway and railroad
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Andrews Dr. over US 40 and CSX RR built?

It was built in 2011, making it 14 years old in 2025.

What condition is Andrews Dr. over US 40 and CSX RR in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in January 2024.

How much traffic does Andrews Dr. over US 40 and CSX RR carry?

About 225 vehicles per day (2020 count), of which roughly 21% are trucks.

How long is Andrews Dr. over US 40 and CSX RR?

The structure is 347 ft (105.7 m) long with a longest span of 170 ft (51.8 m) and a deck 35 ft wide.

Who owns Andrews Dr. over US 40 and CSX RR?

It is owned by the City or Municipal Highway Agency.