US Bridges

FAI 172 SB over Bn RR

Poor

Adams County, Illinois · 1.5MI S I172/US24 · Structure no. 001005000000000

Built
1976
49 years old
Condition
Poor
inspected April 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
288 ft
3 main spans
Daily traffic
3,675
2023 count
Owner
State
State Highway Agency

About this bridge

FAI 172 SB over Bn RR is a prestressed concrete stringer/multi-beam or girder carrying FAI 172 SB over Bn RR in Adams County, Illinois. It was built in 1976, so it is 49 years old, older than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

It carries about 3,675 vehicles a day, roughly 11% of them trucks, projected to reach 3,737 by 2046. The structure is 288 ft (87.9 m) long and 42 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesFAI 172 SB
CrossesBn RR
Location1.5MI S I172/US24
RouteInterstate 172
Coordinates39.98414, -91.3093
Functional classRural Principal Arterial - Interstate

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionApril 2024
Inspection intervalevery 12 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating74.6 US tons
Inventory rating21.8 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length288 ft (87.9 m)
Longest span97 ft (29.7 m)
Deck width42 ft (12.8 m)
Roadway width38 ft (11.7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,675 (2023)
Projected traffic3,737 by 2046
Trucks11%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesRailroad
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was FAI 172 SB over Bn RR built?

It was built in 1976, making it 49 years old in 2025.

What condition is FAI 172 SB over Bn RR in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in April 2024.

How much traffic does FAI 172 SB over Bn RR carry?

About 3,675 vehicles per day (2023 count), of which roughly 11% are trucks.

How long is FAI 172 SB over Bn RR?

The structure is 288 ft (87.9 m) long with a longest span of 97 ft (29.7 m) and a deck 42 ft wide.

Who owns FAI 172 SB over Bn RR?

It is owned by the State Highway Agency.