US Bridges

CR-137 over I-10 (SR-8)

Good

Suwannee County, Florida · CR-137/I-10 · Structure no. 370014

Built
1967
58 years old
Condition
Good
inspected September 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
248 ft
4 main spans
Daily traffic
1,000
2023 count
Owner
State
State Highway Agency

About this bridge

CR-137 over I-10 (SR-8) is a prestressed concrete stringer/multi-beam or girder carrying CR-137 over I-10 (SR-8) in Suwannee County, Florida. It was built in 1967, so it is 58 years old, older than the Florida average of 41.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 1,000 vehicles a day, roughly 7% of them trucks, projected to reach 1,735 by 2045. The structure is 248 ft (75.6 m) long and 35 ft wide. If it were closed, the detour would be 6.8 mi (11 km).

CarriesCR-137
CrossesI-10 (SR-8)
LocationCR-137/I-10
RouteCounty Highway 137
StateFlorida
Coordinates30.28056, -82.82
Functional classRural Major Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionSeptember 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating47.4 US tons
Inventory rating28.5 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20
Structure length248 ft (75.6 m)
Longest span84 ft (25.6 m)
Deck width35 ft (10.7 m)
Roadway width30 ft (9.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic1,000 (2023)
Projected traffic1,735 by 2045
Trucks7%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed6.8 mi (11 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was CR-137 over I-10 (SR-8) built?

It was built in 1967, making it 58 years old in 2025.

What condition is CR-137 over I-10 (SR-8) in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in September 2024.

How much traffic does CR-137 over I-10 (SR-8) carry?

About 1,000 vehicles per day (2023 count), of which roughly 7% are trucks.

How long is CR-137 over I-10 (SR-8)?

The structure is 248 ft (75.6 m) long with a longest span of 84 ft (25.6 m) and a deck 35 ft wide.

Who owns CR-137 over I-10 (SR-8)?

It is owned by the State Highway Agency.