US Bridges

Wheeler Road S.E. over Oxon Run

Fair

District of Columbia, District of Columbia · Wheeler Road over Oxon Rn · Structure no. 0061

Built
1950
75 years old, rebuilt 2004
Condition
Fair
inspected January 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
62 ft
1 main span
Daily traffic
10,383
2018 count
Owner
State
State Highway Agency

About this bridge

Wheeler Road S.E. over Oxon Run is a steel stringer/multi-beam or girder carrying Wheeler Road S.E. over Oxon Run in District of Columbia, District of Columbia. It was built in 1950 and reconstructed in 2004, so it is 75 years old, older than the District of Columbia average of 63.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 10,383 vehicles a day, roughly 1% of them trucks, projected to reach 13,000 by 2027. The structure is 62 ft (18.9 m) long and 58 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesWheeler Road S.E.
CrossesOxon Run
LocationWheeler Road over Oxon Rn
RouteCity Street 0
Coordinates38.83757, -76.99357
Functional classUrban Minor Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJanuary 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation6: Equal to present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Waterway adequacy6: Equal to present minimum criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating72 US tons
Inventory rating43 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20
Structure length62 ft (18.9 m)
Longest span62 ft (18.9 m)
Deck width58 ft (17.8 m)
Roadway width44 ft (13.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic10,383 (2018)
Projected traffic13,000 by 2027
Trucks1%
Lanes on structure4
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedDeck rehabilitation with only incidental widening
Estimated improvement cost$1.8 million
NavigationNo navigation control on waterway

Frequently asked questions

When was Wheeler Road S.E. over Oxon Run built?

It was built in 1950, making it 75 years old in 2025. It was reconstructed in 2004.

What condition is Wheeler Road S.E. over Oxon Run in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in January 2024.

How much traffic does Wheeler Road S.E. over Oxon Run carry?

About 10,383 vehicles per day (2018 count), of which roughly 1% are trucks.

How long is Wheeler Road S.E. over Oxon Run?

The structure is 62 ft (18.9 m) long with a longest span of 62 ft (18.9 m) and a deck 58 ft wide.

Who owns Wheeler Road S.E. over Oxon Run?

It is owned by the State Highway Agency.