US Bridges

INTERSTATE-395 NB over SR 607 Westcott Road

Good

Windham County, Connecticut · 1 MI N of US Route 6 · Structure no. 00528

Built
1962
63 years old, rebuilt 1993
Condition
Good
inspected October 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
61 ft
1 main span
Daily traffic
15,100
2023 count
Owner
State
State Highway Agency

About this bridge

INTERSTATE-395 NB over SR 607 Westcott Road is a steel stringer/multi-beam or girder carrying INTERSTATE-395 NB over SR 607 Westcott Road in Windham County, Connecticut. It was built in 1962 and reconstructed in 1993, so it is 63 years old, older than the Connecticut average of 56.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 15,100 vehicles a day, roughly 16% of them trucks, projected to reach 22,437 by 2043. The structure is 61 ft (18.6 m) long and 45 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesINTERSTATE-395 NB
CrossesSR 607 Westcott Road
Location1 MI N of US Route 6
RouteInterstate 395
Coordinates41.8094, -71.87199
Functional classRural Principal Arterial - Interstate

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionOctober 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating73.5 US tons
Inventory rating56.8 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20
Structure length61 ft (18.6 m)
Longest span56 ft (17.2 m)
Deck width45 ft (13.6 m)
Roadway width41 ft (12.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic15,100 (2023)
Projected traffic22,437 by 2043
Trucks16%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was INTERSTATE-395 NB over SR 607 Westcott Road built?

It was built in 1962, making it 63 years old in 2025. It was reconstructed in 1993.

What condition is INTERSTATE-395 NB over SR 607 Westcott Road in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in October 2024.

How much traffic does INTERSTATE-395 NB over SR 607 Westcott Road carry?

About 15,100 vehicles per day (2023 count), of which roughly 16% are trucks.

How long is INTERSTATE-395 NB over SR 607 Westcott Road?

The structure is 61 ft (18.6 m) long with a longest span of 56 ft (17.2 m) and a deck 45 ft wide.

Who owns INTERSTATE-395 NB over SR 607 Westcott Road?

It is owned by the State Highway Agency.