US Bridges

Route 164 over Interstate 395

Fair

New London County, Connecticut · I-395 Exit No. 85 · Structure no. 00287

Built
1958
67 years old
Condition
Fair
inspected February 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
158 ft
2 main spans
Daily traffic
7,700
2017 count
Owner
State
State Highway Agency

About this bridge

Route 164 over Interstate 395 is a steel stringer/multi-beam or girder carrying Route 164 over Interstate 395 in New London County, Connecticut. It was built in 1958, so it is 67 years old, older than the Connecticut average of 56.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 7,700 vehicles a day, roughly 5% of them trucks, projected to reach 11,441 by 2037. The structure is 158 ft (48.3 m) long and 52 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesRoute 164
CrossesInterstate 395
LocationI-395 Exit No. 85
RouteState Highway 164
Coordinates41.59086, -71.97605
Functional classUrban Minor Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure7 GoodSome minor problems.
Last inspectionFebruary 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating65 US tons
Inventory rating50 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans2
Design loadHS 20
Structure length158 ft (48.3 m)
Longest span81 ft (24.7 m)
Deck width52 ft (16 m)
Roadway width40 ft (12.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic7,700 (2017)
Projected traffic11,441 by 2037
Trucks5%
Lanes on structure3
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Route 164 over Interstate 395 built?

It was built in 1958, making it 67 years old in 2025.

What condition is Route 164 over Interstate 395 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in February 2023.

How much traffic does Route 164 over Interstate 395 carry?

About 7,700 vehicles per day (2017 count), of which roughly 5% are trucks.

How long is Route 164 over Interstate 395?

The structure is 158 ft (48.3 m) long with a longest span of 81 ft (24.7 m) and a deck 52 ft wide.

Who owns Route 164 over Interstate 395?

It is owned by the State Highway Agency.