US Bridges

S330-E210CONNECTOR over E210-N330 Connector Ramp

Good

San Bernardino County, California · 08-SBD-330-R28.78-SBD · Structure no. 54 1097F

Built
1993
32 years old
Condition
Good
inspected December 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
115 ft
1 main span
Daily traffic
10,000
2020 count
Owner
State
State Highway Agency

About this bridge

S330-E210CONNECTOR over E210-N330 Connector Ramp is a prestressed concrete box beam or girders - multiple carrying S330-E210CONNECTOR over E210-N330 Connector Ramp in San Bernardino County, California. It was built in 1993, so it is 32 years old, younger than the California average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 10,000 vehicles a day, roughly 4% of them trucks, projected to reach 12,000 by 2042. The structure is 115 ft (35.1 m) long and 37 ft wide. If it were closed, the detour would be 2.5 mi (4 km).

CarriesS330-E210CONNECTOR
CrossesE210-N330 Connector Ramp
Location08-SBD-330-R28.78-SBD
RouteState Highway 330
Coordinates34.12971, -117.20346
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionDecember 2024
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment4: Meets minimum tolerable limits to be left in place as is
Operating rating57.9 US tons
Inventory rating44.6 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20 + Mod
Structure length115 ft (35.1 m)
Longest span113 ft (34.4 m)
Deck width37 ft (11.4 m)
Roadway width34 ft (10.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic10,000 (2020)
Projected traffic12,000 by 2042
Trucks4%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed2.5 mi (4 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was S330-E210CONNECTOR over E210-N330 Connector Ramp built?

It was built in 1993, making it 32 years old in 2025.

What condition is S330-E210CONNECTOR over E210-N330 Connector Ramp in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in December 2024.

How much traffic does S330-E210CONNECTOR over E210-N330 Connector Ramp carry?

About 10,000 vehicles per day (2020 count), of which roughly 4% are trucks.

How long is S330-E210CONNECTOR over E210-N330 Connector Ramp?

The structure is 115 ft (35.1 m) long with a longest span of 113 ft (34.4 m) and a deck 37 ft wide.

Who owns S330-E210CONNECTOR over E210-N330 Connector Ramp?

It is owned by the State Highway Agency.