Access Road over Drainage Engineer Resrv
FairPosted for loadMonterey County, California · N Dpw on Fence Sec 13W · Structure no. DAPFORLIG000784
- Built
- 2002
- 23 years old
- Condition
- Fair
- inspected October 2023
- Type
- Truss - Thru
- Steel
- Length
- 50 ft
- 1 main span
- Daily traffic
- 1
- 2019 count
- Owner
- Federal
- Army
About this bridge
Access Road over Drainage Engineer Resrv is a steel truss - thru carrying Access Road over Drainage Engineer Resrv in Monterey County, California. It was built in 2002, so it is 23 years old, younger than the California average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.
It carries about 1 vehicles a day, roughly 1% of them trucks, projected to reach 2 by 2044. The structure is 50 ft (15.2 m) long and 15 ft wide.
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Channel and channel protection | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was Access Road over Drainage Engineer Resrv built?
It was built in 2002, making it 23 years old in 2025.
What condition is Access Road over Drainage Engineer Resrv in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in October 2023.
How much traffic does Access Road over Drainage Engineer Resrv carry?
About 1 vehicles per day (2019 count), of which roughly 1% are trucks.
How long is Access Road over Drainage Engineer Resrv?
The structure is 50 ft (15.2 m) long with a longest span of 50 ft (15.2 m) and a deck 15 ft wide.
Who owns Access Road over Drainage Engineer Resrv?
It is owned by the Army.