US Bridges

Huntington DR over Santa Anita Wash

Good

Los Angeles County, California · 0.6MI E/O Santa Anita Ave · Structure no. 53C1814

Built
1958
67 years old
Condition
Good
inspected May 2021
Type
Frame
Concrete
Length
44 ft
1 main span
Daily traffic
27,573
2012 count
Owner
City
City or Municipal Highway Agency

About this bridge

Huntington DR over Santa Anita Wash is a concrete frame carrying Huntington DR over Santa Anita Wash in Los Angeles County, California. It was built in 1958, so it is 67 years old, older than the California average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 27,573 vehicles a day, roughly 2% of them trucks, projected to reach 33,088 by 2041. The structure is 44 ft (13.4 m) long and 90 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesHuntington DR
CrossesSanta Anita Wash
Location0.6MI E/O Santa Anita Ave
RouteCity Street 0L493
Coordinates34.14008, -118.02038
Functional classUrban Other Principal Arterial

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Channel and channel protection9 ExcellentNo problems noted.
Last inspectionMay 2021
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating98.5 US tons
Inventory rating59.3 US tons

Structure

Structure typeFrame
MaterialConcrete
DeckNot applicable
Main spans1
Design loadUnknown
Structure length44 ft (13.4 m)
Longest span30 ft (9.1 m)
Deck width90 ft (27.5 m)
Roadway width69 ft (21.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic27,573 (2012)
Projected traffic33,088 by 2041
Trucks2%
Lanes on structure6
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Huntington DR over Santa Anita Wash built?

It was built in 1958, making it 67 years old in 2025.

What condition is Huntington DR over Santa Anita Wash in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2021.

How much traffic does Huntington DR over Santa Anita Wash carry?

About 27,573 vehicles per day (2012 count), of which roughly 2% are trucks.

How long is Huntington DR over Santa Anita Wash?

The structure is 44 ft (13.4 m) long with a longest span of 30 ft (9.1 m) and a deck 90 ft wide.

Who owns Huntington DR over Santa Anita Wash?

It is owned by the City or Municipal Highway Agency.