S99-E180 Connector over E180-S99 99 N99-W180
FairFresno County, California · 06-FRE-099-21.74-FRE · Structure no. 42 0311F
- Built
- 1995
- 30 years old
- Condition
- Fair
- inspected November 2023
- Type
- Box Beam or Girders - Multiple
- Prestressed Concrete Continuous
- Length
- 597 ft
- 4 main spans
- Daily traffic
- 23,000
- 2018 count
- Owner
- State
- State Highway Agency
About this bridge
S99-E180 Connector over E180-S99 99 N99-W180 is a prestressed concrete continuous box beam or girders - multiple carrying S99-E180 Connector over E180-S99 99 N99-W180 in Fresno County, California. It was built in 1995, so it is 30 years old, younger than the California average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 23,000 vehicles a day, roughly 14% of them trucks, projected to reach 33,000 by 2040. The structure is 597 ft (181.9 m) long and 42 ft wide. If it were closed, the detour would be 0.6 mi (1 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was S99-E180 Connector over E180-S99 99 N99-W180 built?
It was built in 1995, making it 30 years old in 2025.
What condition is S99-E180 Connector over E180-S99 99 N99-W180 in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in November 2023.
How much traffic does S99-E180 Connector over E180-S99 99 N99-W180 carry?
About 23,000 vehicles per day (2018 count), of which roughly 14% are trucks.
How long is S99-E180 Connector over E180-S99 99 N99-W180?
The structure is 597 ft (181.9 m) long with a longest span of 169 ft (51.4 m) and a deck 42 ft wide.
Who owns S99-E180 Connector over E180-S99 99 N99-W180?
It is owned by the State Highway Agency.