S160-E4 Connector over E4-N160 Connect UPRR
FairContra Costa County, California · 04-CC-160-L0.41R-ANT · Structure no. 28 0409F
- Built
- 2016
- 9 years old
- Condition
- Fair
- inspected July 2024
- Type
- Box Beam or Girders - Multiple
- Prestressed Concrete Continuous
- Length
- 1,371 ft
- 7 main spans
- Daily traffic
- 13,600
- 2018 count
- Owner
- State
- State Highway Agency
About this bridge
S160-E4 Connector over E4-N160 Connect UPRR is a prestressed concrete continuous box beam or girders - multiple carrying S160-E4 Connector over E4-N160 Connect UPRR in Contra Costa County, California. It was built in 2016, so it is 9 years old, younger than the California average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 13,600 vehicles a day, roughly 7% of them trucks, projected to reach 17,200 by 2042. The structure is 1,371 ft (417.9 m) long and 47 ft wide. If it were closed, the detour would be 5 mi (8 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 7 Good | Some minor problems. |
| Substructure | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was S160-E4 Connector over E4-N160 Connect UPRR built?
It was built in 2016, making it 9 years old in 2025.
What condition is S160-E4 Connector over E4-N160 Connect UPRR in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2024.
How much traffic does S160-E4 Connector over E4-N160 Connect UPRR carry?
About 13,600 vehicles per day (2018 count), of which roughly 7% are trucks.
How long is S160-E4 Connector over E4-N160 Connect UPRR?
The structure is 1,371 ft (417.9 m) long with a longest span of 220 ft (67.1 m) and a deck 47 ft wide.
Who owns S160-E4 Connector over E4-N160 Connect UPRR?
It is owned by the State Highway Agency.